Hello!Labotery Instrument Co., Ltd.,We are dedicated to serving you!
Consultation hotline 400-044-6660
Shaking incubator accessories
About Us

Labotery Instrument Co., Ltd.

TEL:400-044-6660

TEL:022-87897009

http://en.labotery.com

E-mail:labyq@labotery.com

CQ-Ⅰ/ⅠⅠ

Time:2024-06-28 Popularity: 13

Magnetic drive shaker

Applications:

It is widely used in microbial, viral, bacterial culture, fermentation, hybridization, biochemical reaction and cell tissue research. Magnetic drive shaker(CO2-resistant shaker) is a special horizontal shaker for CO2 incubator, using magnetic drive mode, it can work normally in the high temperature, high humidity and CO2 acid environment in the co2 incubator, but also can be used as a common horizontal shaker.

Performance Overview:

1. Split controller design, easy operation, energy saving and consumption reduction.

The controller is placed outside the incubator and connected to the shaker by a cable. The cable is connected to the shaking host inside the incubator through the test hole of the incubator. It can be used even if there is no power interface in the incubator. Strong magnetic design on the back of the controller shell, the controller can be adsorbed on the surface of the metal shell, easy to operate and observe; Operate and observe shaker operation data without opening the incubator door, saving operation time and reducing temperature fluctuations and CO2 consumption caused by opening and closing the chamber door.

2. Magnetic drive, low energy consumption machine power maximum 20W, environmental protection and energy saving.

Magnetically driven, smooth start-up operation, designed for cell culture, does not produce high liquid shear force to harm cells. Magnetic drive mode, the power is very small, the oscillator operation almost does not produce heat, can effectively ensure that the operation of the equipment will not affect the stability of the temperature in the incubator, and provide a stable and effective operating environment for culture.

3. Belt free drive design to reduce pollution risk.

Technical parameters:

Model

CQ-Ⅰ

CQ-Ⅱ

Shaking  frequency(V)

220V-250V   50/60HZ

Controller

Digital  display LED

Power-off  memory function

yes

Timing  range

0~999(hour)(Set 0 for continuous operation)

Driving  mode

Magnetic  drive

Shaking  frequency

20-350RPM

Shaking  frequency precision()

±1RPM

Orbit(mm)

Ф50

Ф25

Highest  Power

20w

Maximum  load

6kg

Operating  environment requirements

Temperature  4℃-60℃, humidity < 99%RH;

Shaking  Plate Size(mm)

370×350

Main  engine dimensions(mm)

370×370×90

Maximum  number of flask(ml)

50×30or100ml×20or150ml×20or200ml×16or250ml×16or500ml×9or1000ml×6

or2000ml×4or3000ml×3or5000ml×1

400-044-6660